Show Hamamatsu Avalanche Photo Diode 3006033605 - Archived data from Tue, 11. August 2020 18:07:04 CEST
This is all the information about APD 3006033605. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 3006033605 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | G11 |
Break-through voltage: | 413 V |
Voltage for Gain 100 (T=+25°C): | 385.7 V |
Dark current: | 22.7 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 116 |
Position in Box: | 43 |
EP1 batch: | 124 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 384.8524671 V T = -25 °C: 349.3083946 V |
Voltage for Gain 150: | T = +20 °C: 392.7295433 V T = -25 °C: 356.6739559 V |
Voltage for Gain 200: | T = +20 °C: 397.1027407 V T = -25 °C: 360.8856055 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.643444482 V-1 T = -25 °C: 4.750111744 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.165596793 V-1 T = -25 °C: 9.680869672 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.33117869 V-1 T = -25 °C: 14.95966819 V-1 |
Break-through voltage: | T = +20 °C: 412.2062708 V T = -25 °C: 375.8191806 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:03:24 CET | jreher | Updated box and position via API. |
11. Aug 2020 18:07:04 CEST | jreher | Updated APD characteristics via API. |
11. Aug 2020 17:49:34 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:33:45 CEST | jreher | Updated APD batch assignment via API. |
21. Jul 2020 14:33:18 CEST | jreher | Updated APD batch assignment via API. |
02. Mar 2020 16:15:17 CET | vwerner | Updated APD batch assignment via API. |
29. Nov 2019 11:47:11 CET | jreher | Updated APD location via API. |
27. Nov 2019 19:49:12 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:20:10 CET | jreher | Updated box and position via API. |
27. Aug 2019 12:09:06 CEST | jgrochowski | Updated APD batch assignment via API. |
05. Jul 2019 13:51:50 CEST | jreher | Updated APD location via API. |
03. Jan 2019 00:14:24 CET | Tobias | Corrected dark current unit. |
06. Jul 2018 22:38:49 CEST | Tobias | Imported from Hamamatsu datasheet. |