RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3005033510 - Archived data from Tue, 11. August 2020 18:06:51 CEST


This is all the information about APD 3005033510. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3005033510
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F04
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 383.9 V
Dark current: 18.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 115
Position in Box: 31
EP1 batch: 122
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 383.6072554 V     T = -25 °C: 348.5913252 V
Voltage for Gain 150: T = +20 °C: 391.509129 V     T = -25 °C: 355.9192146 V
Voltage for Gain 200: T = +20 °C: 395.8979066 V     T = -25 °C: 360.0217411 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.389550096 V-1     T = -25 °C: 4.751908684 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.432355854 V-1     T = -25 °C: 9.970783791 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.61496394 V-1     T = -25 °C: 15.36418165 V-1
Break-through voltage: T = +20 °C: 410.9548526 V     T = -25 °C: 374.5428024 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:03:14 CET jreher Updated box and position via API.
11. Aug 2020 18:06:51 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:49:28 CEST jreher Updated APD location via API.
02. Mar 2020 15:53:45 CET vwerner Updated APD batch assignment via API.
29. Nov 2019 11:47:06 CET jreher Updated APD location via API.
27. Nov 2019 19:49:00 CET jreher Updated APD location via API.
25. Nov 2019 17:20:04 CET jreher Updated box and position via API.
27. Aug 2019 12:09:56 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:51:41 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:23 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:48 CEST Tobias Imported from Hamamatsu datasheet.