RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3005033487 - Archived data from Fri, 05. February 2021 11:03:12 CET


This is all the information about APD 3005033487. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3005033487
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: H07
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 381.9 V
Dark current: 22 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 115
Position in Box: 11
EP1 batch: 121
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.8045941 V     T = -25 °C: 346.4838597 V
Voltage for Gain 150: T = +20 °C: 389.664258 V     T = -25 °C: 353.8985127 V
Voltage for Gain 200: T = +20 °C: 394.0400622 V     T = -25 °C: 358.069793 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.683653115 V-1     T = -25 °C: 4.726245832 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.249727741 V-1     T = -25 °C: 9.555648019 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.46525161 V-1     T = -25 °C: 15.04695402 V-1
Break-through voltage: T = +20 °C: 406.2685621 V     T = -25 °C: 373.6030109 V
   
Notes:


Version history

Time Author Change comment
09. Feb 2021 11:21:41 CET jreher Assigned to capsule by script
05. Feb 2021 11:03:12 CET jreher Updated box and position via API.
18. Dec 2020 13:59:40 CET jreher Updated box and position via API.
11. Aug 2020 18:06:47 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:49:26 CEST jreher Updated APD location via API.
25. Feb 2020 16:44:11 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:04 CET jreher Updated APD location via API.
27. Nov 2019 19:48:58 CET jreher Updated APD location via API.
25. Nov 2019 17:20:02 CET jreher Updated box and position via API.
27. Aug 2019 12:10:15 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:51:40 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:22 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:48 CEST Tobias Imported from Hamamatsu datasheet.