RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3005033486 - Archived data from Fri, 05. February 2021 11:03:12 CET


This is all the information about APD 3005033486. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3005033486
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G07
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.3 V
Dark current: 22.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 115
Position in Box: 10
EP1 batch: 121
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.3417223 V     T = -25 °C: 346.077431 V
Voltage for Gain 150: T = +20 °C: 389.1866237 V     T = -25 °C: 353.4725474 V
Voltage for Gain 200: T = +20 °C: 393.572986 V     T = -25 °C: 357.61975 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.511632224 V-1     T = -25 °C: 4.889495113 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.824586826 V-1     T = -25 °C: 9.092881248 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.409628 V-1     T = -25 °C: 16.06350579 V-1
Break-through voltage: T = +20 °C: 409.1484122 V     T = -25 °C: 373.0126057 V
   
Notes:


Version history

Time Author Change comment
27. Jun 2022 12:42:38 CEST oafedulidis Assigned to capsule by script
16. Jun 2021 16:03:54 CEST oafedulidis Updated box and position via API.
16. Jun 2021 16:00:10 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:52:50 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:03:12 CET jreher Updated box and position via API.
11. Aug 2020 18:06:47 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:49:26 CEST jreher Updated APD location via API.
25. Feb 2020 16:44:11 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:04 CET jreher Updated APD location via API.
27. Nov 2019 19:48:58 CET jreher Updated APD location via API.
25. Nov 2019 17:20:02 CET jreher Updated box and position via API.
27. Aug 2019 12:10:15 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:51:40 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:22 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:48 CEST Tobias Imported from Hamamatsu datasheet.