RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3004033441 - Archived data from Tue, 11. August 2020 18:06:40 CEST


This is all the information about APD 3004033441. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3004033441
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G03
Break-through voltage: 419 V
Voltage for Gain 100 (T=+25°C): 393.5 V
Dark current: 22.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 114
Position in Box: 24
EP1 batch: 120
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 393.6515361 V     T = -25 °C: 357.3838623 V
Voltage for Gain 150: T = +20 °C: 401.5393435 V     T = -25 °C: 365.042314 V
Voltage for Gain 200: T = +20 °C: 405.938183 V     T = -25 °C: 369.2614155 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.665541141 V-1     T = -25 °C: 4.377225312 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.171673186 V-1     T = -25 °C: 8.72882808 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.48662036 V-1     T = -25 °C: 14.64692891 V-1
Break-through voltage: T = +20 °C: 421.2990412 V     T = -25 °C: 385.0201117 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:03:05 CET jreher Updated box and position via API.
11. Aug 2020 18:06:40 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:49:23 CEST jreher Updated APD location via API.
25. Feb 2020 16:44:38 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:02 CET jreher Updated APD location via API.
27. Nov 2019 19:48:48 CET jreher Updated APD location via API.
25. Nov 2019 17:19:57 CET jreher Updated box and position via API.
27. Aug 2019 12:10:39 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:51:33 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:21 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:47 CEST Tobias Imported from Hamamatsu datasheet.