RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3003033361 - Archived data from Fri, 05. February 2021 11:02:57 CET


This is all the information about APD 3003033361. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3003033361
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D05
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 378.5 V
Dark current: 16.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 113
Position in Box: 13
EP1 batch: 118
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 378.235885 V     T = -25 °C: 343.944326 V
Voltage for Gain 150: T = +20 °C: 386.1382283 V     T = -25 °C: 351.1730106 V
Voltage for Gain 200: T = +20 °C: 390.5521236 V     T = -25 °C: 355.2330395 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.483913307 V-1     T = -25 °C: 5.021506978 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.738139519 V-1     T = -25 °C: 9.451715414 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.08871544 V-1     T = -25 °C: 15.01621309 V-1
Break-through voltage: T = +20 °C: 406.5919187 V     T = -25 °C: 370.3528709 V
   
Notes:


Version history

Time Author Change comment
03. May 2021 10:26:22 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:02:57 CET jreher Updated box and position via API.
11. Aug 2020 18:06:29 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:49:18 CEST jreher Updated APD location via API.
25. Feb 2020 17:04:14 CET vwerner Updated APD batch assignment via API.
29. Nov 2019 11:46:57 CET jreher Updated APD location via API.
27. Nov 2019 19:48:37 CET jreher Updated APD location via API.
25. Nov 2019 17:19:52 CET jreher Updated box and position via API.
27. Aug 2019 12:11:17 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:51:25 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:19 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:46 CEST Tobias Imported from Hamamatsu datasheet.