Subdetector specification:  
Serial: 3003033359
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D04
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.9 V
Dark current: 15.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 113
Position in Box: 11
EP1 batch: 118
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.9200329 V     T = -25 °C: 344.77985 V
Voltage for Gain 150: T = +20 °C: 387.787509 V     T = -25 °C: 352.1693513 V
Voltage for Gain 200: T = +20 °C: 392.1784783 V     T = -25 °C: 356.3263564 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.62894233 V-1     T = -25 °C: 5.002416725 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.050567014 V-1     T = -25 °C: 9.26680988 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.08507634 V-1     T = -25 °C: 14.57589541 V-1
Break-through voltage: T = +20 °C: 407.7097931 V     T = -25 °C: 371.5156681 V
   
Notes:


Version history

Time Author Change comment
10. Jun 2022 12:15:42 CEST oafedulidis Assigned to capsule by script
27. Aug 2021 10:30:47 CEST oafedulidis Updated box and position via API.
03. May 2021 10:26:22 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:02:57 CET jreher Updated box and position via API.
11. Aug 2020 18:06:28 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:49:18 CEST jreher Updated APD location via API.
25. Feb 2020 17:04:14 CET vwerner Updated APD batch assignment via API.
29. Nov 2019 11:46:57 CET jreher Updated APD location via API.
27. Nov 2019 19:48:36 CET jreher Updated APD location via API.
25. Nov 2019 17:19:52 CET jreher Updated box and position via API.
27. Aug 2019 12:11:17 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:51:25 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:19 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:46 CEST Tobias Imported from Hamamatsu datasheet.