Show Hamamatsu Avalanche Photo Diode 3002033320 - Archived data from Tue, 11. August 2020 17:46:47 CEST


This is all the information about APD 3002033320. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3002033320
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C13
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 386.7 V
Dark current: 19.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 112
Position in Box: 32
EP1 batch: 117
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.7809786 V     T = -25 °C: 350.8734155 V
Voltage for Gain 150: T = +20 °C: 394.6399353 V     T = -25 °C: 358.3534881 V
Voltage for Gain 200: T = +20 °C: 398.9976205 V     T = -25 °C: 362.5401444 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.637852507 V-1     T = -25 °C: 4.887162207 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.224629823 V-1     T = -25 °C: 8.989187857 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.39881452 V-1     T = -25 °C: 15.85440163 V-1
Break-through voltage: T = +20 °C: 414.6444699 V     T = -25 °C: 378.0924053 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:02:51 CET jreher Updated box and position via API.
11. Aug 2020 17:46:47 CEST jreher Updated APD characteristics via API.
03. Dec 2019 15:03:11 CET jreher Updated APD location via API.
29. Nov 2019 11:46:55 CET jreher Updated APD location via API.
27. Nov 2019 19:48:27 CET jreher Updated APD location via API.
25. Nov 2019 17:19:48 CET jreher Updated box and position via API.
14. Nov 2019 17:31:23 CET spankonin Updated APD batch assignment via API.
27. Aug 2019 12:11:47 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:51:18 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:18 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:46 CEST Tobias Imported from Hamamatsu datasheet.