RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3002033276 - Archived data from Tue, 11. August 2020 17:46:40 CEST


This is all the information about APD 3002033276. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3002033276
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G12
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 389.3 V
Dark current: 21.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 111
Position in Box: 45
EP1 batch: 116
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 389.1226591 V     T = -25 °C: 353.3418551 V
Voltage for Gain 150: T = +20 °C: 396.9401252 V     T = -25 °C: 360.8026085 V
Voltage for Gain 200: T = +20 °C: 401.2894839 V     T = -25 °C: 364.9823235 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.546268674 V-1     T = -25 °C: 4.707462749 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.000964515 V-1     T = -25 °C: 9.491872221 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.94248812 V-1     T = -25 °C: 14.93056315 V-1
Break-through voltage: T = +20 °C: 416.2583955 V     T = -25 °C: 380.0037626 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:02:44 CET jreher Updated box and position via API.
11. Aug 2020 17:46:40 CEST jreher Updated APD characteristics via API.
03. Dec 2019 15:02:43 CET jreher Updated APD location via API.
29. Nov 2019 11:46:52 CET jreher Updated APD location via API.
27. Nov 2019 19:48:17 CET jreher Updated APD location via API.
25. Nov 2019 17:19:44 CET jreher Updated box and position via API.
14. Nov 2019 17:31:07 CET spankonin Updated APD batch assignment via API.
27. Aug 2019 12:12:12 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:51:11 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:17 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:45 CEST Tobias Imported from Hamamatsu datasheet.