Serial: 3001033227
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B13
Break-through voltage: 417 V
Voltage for Gain 100 (T=+25°C): 391.9 V
Dark current: 18.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 111
Position in Box: 17
EP1 batch: 115
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 392.7201227 V     T = -25 °C: 356.4705394 V
Voltage for Gain 150: T = +20 °C: 400.5460286 V     T = -25 °C: 364.0598849 V
Voltage for Gain 200: T = +20 °C: 404.8721318 V     T = -25 °C: 368.3279897 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.685469935 V-1     T = -25 °C: 4.602861925 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.412941414 V-1     T = -25 °C: 9.121041856 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.73742386 V-1     T = -25 °C: 14.17907488 V-1
Break-through voltage: T = +20 °C: 419.6812028 V     T = -25 °C: 383.3716463 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:02:41 CET jreher Updated box and position via API.
11. Aug 2020 17:46:34 CEST jreher Updated APD characteristics via API.
03. Dec 2019 15:02:41 CET jreher Updated APD location via API.
29. Nov 2019 11:46:50 CET jreher Updated APD location via API.
27. Nov 2019 19:48:14 CET jreher Updated APD location via API.
25. Nov 2019 17:19:42 CET jreher Updated box and position via API.
14. Nov 2019 17:30:44 CET spankonin Updated APD batch assignment via API.
23. Aug 2019 12:02:40 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:51:09 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:16 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:44 CEST Tobias Imported from Hamamatsu datasheet.