RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2911033215 - Archived data from Tue, 11. August 2020 17:46:34 CEST


This is all the information about APD 2911033215. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2911033215
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C11
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.9 V
Dark current: 7.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 111
Position in Box: 12
EP1 batch: 115
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.4298862 V     T = -25 °C: 346.8328878 V
Voltage for Gain 150: T = +20 °C: 390.2018463 V     T = -25 °C: 354.1737563 V
Voltage for Gain 200: T = +20 °C: 394.5249903 V     T = -25 °C: 358.2872475 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.450766493 V-1     T = -25 °C: 4.962820661 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.767508907 V-1     T = -25 °C: 9.238792601 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.27290038 V-1     T = -25 °C: 16.6502991 V-1
Break-through voltage: T = +20 °C: 409.4840099 V     T = -25 °C: 373.0658952 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:02:40 CET jreher Updated box and position via API.
11. Aug 2020 17:46:34 CEST jreher Updated APD characteristics via API.
03. Dec 2019 15:02:40 CET jreher Updated APD location via API.
29. Nov 2019 11:46:49 CET jreher Updated APD location via API.
27. Nov 2019 19:48:14 CET jreher Updated APD location via API.
25. Nov 2019 17:19:41 CET jreher Updated box and position via API.
14. Nov 2019 17:30:43 CET spankonin Updated APD batch assignment via API.
23. Aug 2019 12:02:39 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:51:08 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:16 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:44 CEST Tobias Imported from Hamamatsu datasheet.