RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2903032662 - Archived data from Tue, 11. August 2020 18:00:13 CEST


This is all the information about APD 2903032662. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2903032662
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: A06
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 386.5 V
Dark current: 5.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 109
Position in Box: 5
EP1 batch: 111
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.7051082 V     T = -25 °C: 350.7755315 V
Voltage for Gain 150: T = +20 °C: 394.5879903 V     T = -25 °C: 358.2879188 V
Voltage for Gain 200: T = +20 °C: 398.9471 V     T = -25 °C: 362.5184722 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.382636477 V-1     T = -25 °C: 4.935966133 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.50374959 V-1     T = -25 °C: 9.105484246 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.74809926 V-1     T = -25 °C: 16.08711995 V-1
Break-through voltage: T = +20 °C: 414.2957888 V     T = -25 °C: 378.1738946 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:02:23 CET jreher Updated box and position via API.
11. Aug 2020 18:00:13 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:49:07 CEST jreher Updated APD location via API.
28. Jan 2020 15:48:20 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:46:42 CET jreher Updated APD location via API.
28. Nov 2019 12:01:17 CET jreher Updated APD location via API.
25. Nov 2019 17:19:35 CET jreher Updated box and position via API.
23. Aug 2019 12:00:04 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:50:00 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:12 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:41 CEST Tobias Imported from Hamamatsu datasheet.