Show Hamamatsu Avalanche Photo Diode 2903032622 - Archived data from Fri, 23. August 2019 11:59:46 CEST
This is all the information about APD 2903032622. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2903032622 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum Box 98 |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | F04 |
Break-through voltage: | 407 V |
Voltage for Gain 100 (T=+25°C): | 378.4 V |
Dark current: | 5 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 108 |
Position in Box: | 23 |
EP1 batch: | 110 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
29. Mar 2022 12:39:08 CEST | oafedulidis | Assigned to capsule by script |
16. Jun 2021 16:03:08 CEST | oafedulidis | Updated box and position via API. |
16. Jun 2021 15:59:34 CEST | oafedulidis | Updated box and position via API. |
16. Jun 2021 15:52:11 CEST | oafedulidis | Updated box and position via API. |
05. Feb 2021 11:02:17 CET | jreher | Updated box and position via API. |
11. Aug 2020 18:06:12 CEST | jreher | Updated APD characteristics via API. |
11. Aug 2020 17:49:04 CEST | jreher | Updated APD location via API. |
25. Feb 2020 17:02:04 CET | vwerner | Updated APD batch assignment via API. |
29. Nov 2019 11:46:39 CET | jreher | Updated APD location via API. |
28. Nov 2019 12:01:14 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:19:32 CET | jreher | Updated box and position via API. |
23. Aug 2019 11:59:46 CEST | jgrochowski | Updated APD batch assignment via API. |
05. Jul 2019 13:49:58 CEST | jreher | Updated APD location via API. |
03. Jan 2019 00:14:11 CET | Tobias | Corrected dark current unit. |
06. Jul 2018 22:38:41 CEST | Tobias | Imported from Hamamatsu datasheet. |