RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2902032586 - Archived data from Tue, 11. August 2020 18:06:05 CEST


This is all the information about APD 2902032586. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2902032586
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E12
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 384.2 V
Dark current: 10.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 108
Position in Box: 8
EP1 batch: 110
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 384.6874868 V     T = -25 °C: 348.5845359 V
Voltage for Gain 150: T = +20 °C: 392.5335904 V     T = -25 °C: 356.0592581 V
Voltage for Gain 200: T = +20 °C: 396.8811747 V     T = -25 °C: 360.2715171 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.693368989 V-1     T = -25 °C: 4.617752559 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.344561926 V-1     T = -25 °C: 9.221761137 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.6608296 V-1     T = -25 °C: 14.40227653 V-1
Break-through voltage: T = +20 °C: 411.996092 V     T = -25 °C: 375.376016 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:02:15 CET jreher Updated box and position via API.
11. Aug 2020 18:06:05 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:49:02 CEST jreher Updated APD location via API.
25. Feb 2020 16:59:13 CET vwerner Updated APD batch assignment via API.
29. Nov 2019 11:46:38 CET jreher Updated APD location via API.
28. Nov 2019 12:01:13 CET jreher Updated APD location via API.
25. Nov 2019 17:19:30 CET jreher Updated box and position via API.
23. Aug 2019 11:59:45 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:49:57 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:11 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:40 CEST Tobias Imported from Hamamatsu datasheet.