Show Hamamatsu Avalanche Photo Diode 2902032555 - Archived data from Fri, 05. February 2021 11:01:31 CET


This is all the information about APD 2902032555. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2902032555
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F03
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 378.2 V
Dark current: 6.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 102
Position in Box: 30
EP1 batch: 100
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 377.8487059 V     T = -25 °C: 342.7639242 V
Voltage for Gain 150: T = +20 °C: 385.701396 V     T = -25 °C: 350.1140558 V
Voltage for Gain 200: T = +20 °C: 390.1126604 V     T = -25 °C: 354.2527532 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.624458559 V-1     T = -25 °C: 5.091212748 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.056074838 V-1     T = -25 °C: 9.436948188 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.18499903 V-1     T = -25 °C: 14.6633738 V-1
Break-through voltage: T = +20 °C: 406.1196382 V     T = -25 °C: 369.8167167 V
   
Notes:


Version history

Time Author Change comment
19. May 2022 15:26:38 CEST oafedulidis Assigned to capsule by script
17. May 2021 09:16:19 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:01:31 CET jreher Updated box and position via API.
11. Aug 2020 18:05:46 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:48:37 CEST jreher Updated APD location via API.
20. Feb 2020 15:16:05 CET vwerner Updated APD batch assignment via API.
29. Nov 2019 11:46:17 CET jreher Updated APD location via API.
28. Nov 2019 12:01:11 CET jreher Updated APD location via API.
25. Nov 2019 17:19:04 CET jreher Updated box and position via API.
20. Aug 2019 12:47:57 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:49:54 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:09 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:38 CEST Tobias Imported from Hamamatsu datasheet.