RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2902032538 - Archived data from Tue, 11. August 2020 18:05:43 CEST


This is all the information about APD 2902032538. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2902032538
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C08
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.4 V
Dark current: 7.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 102
Position in Box: 15
EP1 batch: 99
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.7610433 V     T = -25 °C: 346.2369549 V
Voltage for Gain 150: T = +20 °C: 389.6530849 V     T = -25 °C: 353.6666005 V
Voltage for Gain 200: T = +20 °C: 394.0349399 V     T = -25 °C: 357.8271955 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.667480005 V-1     T = -25 °C: 4.788170744 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.246546761 V-1     T = -25 °C: 9.745076232 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.39610202 V-1     T = -25 °C: 15.4645706 V-1
Break-through voltage: T = +20 °C: 409.6303998 V     T = -25 °C: 373.087905 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:01:29 CET jreher Updated box and position via API.
11. Aug 2020 18:05:43 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:48:36 CEST jreher Updated APD location via API.
20. Feb 2020 15:12:44 CET vwerner Updated APD batch assignment via API.
29. Nov 2019 11:46:16 CET jreher Updated APD location via API.
28. Nov 2019 12:01:10 CET jreher Updated APD location via API.
25. Nov 2019 17:19:03 CET jreher Updated box and position via API.
20. Aug 2019 12:47:31 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:49:53 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:09 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:37 CEST Tobias Imported from Hamamatsu datasheet.