RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2901032499 - Archived data from Tue, 11. August 2020 18:05:40 CEST


This is all the information about APD 2901032499. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2901032499
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B03
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 385.4 V
Dark current: 5.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 101
Position in Box: 48
EP1 batch: 99
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.2267413 V     T = -25 °C: 349.4312288 V
Voltage for Gain 150: T = +20 °C: 393.07906 V     T = -25 °C: 356.9048293 V
Voltage for Gain 200: T = +20 °C: 397.4524245 V     T = -25 °C: 361.0978936 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.52734761 V-1     T = -25 °C: 4.715518893 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.951458557 V-1     T = -25 °C: 9.476536856 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.88305652 V-1     T = -25 °C: 14.99453595 V-1
Break-through voltage: T = +20 °C: 411.0725402 V     T = -25 °C: 376.5588508 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:01:26 CET jreher Updated box and position via API.
11. Aug 2020 18:05:40 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:48:34 CEST jreher Updated APD location via API.
20. Feb 2020 15:12:43 CET vwerner Updated APD batch assignment via API.
29. Nov 2019 11:46:14 CET jreher Updated APD location via API.
28. Nov 2019 12:01:09 CET jreher Updated APD location via API.
25. Nov 2019 17:19:00 CET jreher Updated box and position via API.
20. Aug 2019 12:47:30 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:49:52 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:08 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:37 CEST Tobias Imported from Hamamatsu datasheet.