Subdetector specification:  
Serial: 2901032484
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F12
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 380.4 V
Dark current: 9.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 101
Position in Box: 34
EP1 batch: 98
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.4306673 V     T = -25 °C: 345.0022616 V
Voltage for Gain 150: T = +20 °C: 388.2552711 V     T = -25 °C: 352.3660772 V
Voltage for Gain 200: T = +20 °C: 392.6100392 V     T = -25 °C: 356.5479102 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.445823922 V-1     T = -25 °C: 4.772549446 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.736983878 V-1     T = -25 °C: 9.209655103 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.2202766 V-1     T = -25 °C: 15.93927756 V-1
Break-through voltage: T = +20 °C: 408.4946333 V     T = -25 °C: 372.1593644 V
   
Notes:


Version history

Time Author Change comment
27. Jun 2022 12:44:22 CEST oafedulidis Assigned to capsule by script
21. Apr 2021 11:02:16 CEST jreher Updated box and position via API.
05. Feb 2021 11:01:24 CET jreher Updated box and position via API.
11. Aug 2020 18:05:37 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:48:33 CEST jreher Updated APD location via API.
20. Feb 2020 15:00:04 CET vwerner Updated APD batch assignment via API.
29. Nov 2019 11:46:13 CET jreher Updated APD location via API.
28. Nov 2019 12:01:08 CET jreher Updated APD location via API.
25. Nov 2019 17:18:59 CET jreher Updated box and position via API.
20. Aug 2019 12:47:06 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:49:51 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:08 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:36 CEST Tobias Imported from Hamamatsu datasheet.