Subdetector specification: | |
---|---|
Serial: | 2901032458 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum Box 44 |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | C05 |
Break-through voltage: | 411 V |
Voltage for Gain 100 (T=+25°C): | 382.8 V |
Dark current: | 5.4 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 44 |
Position in Box: | 5 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 24. Jul 2018 |
Sent for analysis after irradiation: | 21. Aug 2018 |
Return for assembly: | none |
Irradiation: | |
Date: | 16. Aug 2018 |
Dose used: | 30 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 17. Aug 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: | foam |
Version history
Time | Author | Change comment |
---|---|---|
22. Feb 2021 11:10:47 CET | jreher | Updated box and position via API. |
05. Feb 2021 11:01:21 CET | jreher | Updated box and position via API. |
05. Feb 2021 10:53:49 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:19:37 CET | jreher | Updated box and position via API. |
06. Oct 2020 18:39:33 CEST | jreher | |
11. Aug 2020 17:26:48 CEST | jreher | Updated APD characteristics via API. |
04. Aug 2020 15:48:17 CEST | jreher | Updated box and position via API. |
29. Nov 2019 10:57:24 CET | jreher | Updated APD location via API. |
27. Nov 2019 19:36:47 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:18:57 CET | jreher | Updated box and position via API. |
25. Nov 2019 17:14:23 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:11:34 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:48:40 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:33:36 CEST | jreher | Updated APD batch assignment via API. |
03. Jan 2019 00:14:07 CET | Tobias | Corrected dark current unit. |
21. Aug 2018 12:02:45 CEST | markus.moritz | |
20. Jun 2018 13:36:35 CEST | Tobias | Imported from Hamamatsu datasheet. |