RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2819032342 - Archived data from Tue, 11. August 2020 18:05:21 CEST


This is all the information about APD 2819032342. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2819032342
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F09
Break-through voltage: 405 V
Voltage for Gain 100 (T=+25°C): 379 V
Dark current: 5.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 99
Position in Box: 33
EP1 batch: 96
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 378.6457346 V     T = -25 °C: 343.5620945 V
Voltage for Gain 150: T = +20 °C: 386.4423391 V     T = -25 °C: 350.8900645 V
Voltage for Gain 200: T = +20 °C: 390.7735156 V     T = -25 °C: 354.9905049 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.4301678 V-1     T = -25 °C: 4.763641779 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.681249049 V-1     T = -25 °C: 9.690556713 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.11002494 V-1     T = -25 °C: 15.44142898 V-1
Break-through voltage: T = +20 °C: 406.2812422 V     T = -25 °C: 370.2872354 V
   
Notes:


Version history

Time Author Change comment
16. Nov 2021 10:32:20 CET oafedulidis Assigned to capsule by script
27. Aug 2021 11:15:56 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:01:09 CET jreher Updated box and position via API.
11. Aug 2020 18:05:21 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:36 CEST jreher Updated APD location via API.
17. Feb 2020 17:49:39 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:51:02 CET jreher Updated APD location via API.
28. Nov 2019 12:01:23 CET jreher Updated APD location via API.
25. Nov 2019 17:18:50 CET jreher Updated box and position via API.
20. Aug 2019 12:46:06 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:49:44 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:05 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:32 CEST Tobias Imported from Hamamatsu datasheet.