RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2909033085 - Archived data from Tue, 11. August 2020 18:05:16 CEST


This is all the information about APD 2909033085. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2909033085
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E06
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 380.6 V
Dark current: 6.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 99
Position in Box: 4
EP1 batch: 95
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.4144423 V     T = -25 °C: 345.1708639 V
Voltage for Gain 150: T = +20 °C: 388.207406 V     T = -25 °C: 352.5290097 V
Voltage for Gain 200: T = +20 °C: 392.5561825 V     T = -25 °C: 356.6466039 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.5320504 V-1     T = -25 °C: 4.902758432 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.91809578 V-1     T = -25 °C: 9.110084606 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.5957498 V-1     T = -25 °C: 16.33159231 V-1
Break-through voltage: T = +20 °C: 408.3274546 V     T = -25 °C: 372.1061791 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:01:05 CET jreher Updated box and position via API.
11. Aug 2020 18:05:16 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:33 CEST jreher Updated APD location via API.
17. Feb 2020 17:50:00 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:51:00 CET jreher Updated APD location via API.
27. Nov 2019 19:46:27 CET jreher Updated APD location via API.
25. Nov 2019 17:18:48 CET jreher Updated box and position via API.
24. Oct 2019 12:38:14 CEST spankonin Updated APD location via API.
20. Aug 2019 12:45:42 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:14:04 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:31 CEST Tobias Imported from Hamamatsu datasheet.