Show Hamamatsu Avalanche Photo Diode 2908032975 - Archived data from Fri, 05. February 2021 11:02:00 CET


This is all the information about APD 2908032975. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2908032975
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F10
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 379.6 V
Dark current: 10.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 106
Position in Box: 13
EP1 batch: 107
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.1105295 V     T = -25 °C: 343.8138062 V
Voltage for Gain 150: T = +20 °C: 386.9012247 V     T = -25 °C: 351.1479176 V
Voltage for Gain 200: T = +20 °C: 391.2412754 V     T = -25 °C: 355.2632691 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.617538002 V-1     T = -25 °C: 5.032953311 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.135028156 V-1     T = -25 °C: 9.473921551 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.30904634 V-1     T = -25 °C: 15.02867227 V-1
Break-through voltage: T = +20 °C: 406.5485244 V     T = -25 °C: 370.3419236 V
   
Notes:


Version history

Time Author Change comment
15. Feb 2021 15:39:33 CET jreher Assigned to capsule by script
05. Feb 2021 11:02:00 CET jreher Updated box and position via API.
18. Dec 2020 14:01:05 CET jreher Updated box and position via API.
11. Aug 2020 18:00:04 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:48:54 CEST jreher Updated APD location via API.
28. Jan 2020 15:35:13 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:46:31 CET jreher Updated APD location via API.
27. Nov 2019 19:47:29 CET jreher Updated APD location via API.
25. Nov 2019 17:19:21 CET jreher Updated box and position via API.
23. Aug 2019 11:58:36 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:50:45 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:01 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:27 CEST Tobias Imported from Hamamatsu datasheet.