RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0804007475 - Archived data from Tue, 11. August 2020 17:43:02 CEST


This is all the information about APD 0804007475. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0804007475
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C07
Break-through voltage: 416 V
Voltage for Gain 100 (T=+25°C): 387.1 V
Dark current: 3.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 236
Position in Box: 15
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Aug 2019
Sent for analysis after irradiation: 15. Oct 2019
Return for assembly: none
   
Irradiation:  
Date: 09. Oct 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 12. Oct 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 387.9250573 V     T = -25 °C: 351.9094618 V
Voltage for Gain 150: T = +20 °C: 395.809806 V     T = -25 °C: 359.5678546 V
Voltage for Gain 200: T = +20 °C: 400.1774606 V     T = -25 °C: 363.4818105 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.614075242 V-1     T = -25 °C: 4.64993548 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.134948746 V-1     T = -25 °C: 9.582377912 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.24979965 V-1     T = -25 °C: 15.91004632 V-1
Break-through voltage: T = +20 °C: 415.3601192 V     T = -25 °C: 378.6815783 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:18:42 CET jreher Updated box and position via API.
11. Aug 2020 17:43:02 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:30:19 CEST jreher Updated box and position via API.
16. Jan 2020 12:06:10 CET jreher Updated date sent for analysis after screening via API.
16. Jan 2020 12:04:20 CET jreher Updated annealing info via API.
16. Jan 2020 12:01:31 CET jreher Updated irradiation info via API.
16. Jan 2020 11:58:38 CET jreher Updated arrival for irradiation via API.
16. Jan 2020 11:57:37 CET jreher Updated arrival for irradiation via API.
27. Nov 2019 20:10:50 CET jreher Updated APD location via API.
25. Nov 2019 17:29:13 CET jreher Updated box and position via API.
22. Oct 2019 16:36:27 CEST spankonin Updated APD batch assignment via API.
22. Oct 2019 16:17:09 CEST spankonin Updated APD location via API.
22. Jun 2016 15:22:38 CEST Tobias Imported from Hamamatsu datasheet.