RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2907032912 - Archived data from Tue, 11. August 2020 17:59:59 CEST


This is all the information about APD 2907032912. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2907032912
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E09
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 378.8 V
Dark current: 9.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 113
Position in Box: 45
EP1 batch: 106
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 378.453511 V     T = -25 °C: 343.2403198 V
Voltage for Gain 150: T = +20 °C: 386.3073597 V     T = -25 °C: 350.6356963 V
Voltage for Gain 200: T = +20 °C: 390.6764973 V     T = -25 °C: 354.77381 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.450671982 V-1     T = -25 °C: 4.806423398 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.642420229 V-1     T = -25 °C: 9.766928258 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.90631844 V-1     T = -25 °C: 15.54802507 V-1
Break-through voltage: T = +20 °C: 406.6449458 V     T = -25 °C: 370.3395184 V
   
Notes:


Version history

Time Author Change comment
29. Mar 2022 12:39:16 CEST oafedulidis Assigned to capsule by script
16. Jun 2021 16:03:08 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:59:33 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:52:11 CEST oafedulidis Updated box and position via API.
03. May 2021 10:26:26 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:01:54 CET jreher Updated box and position via API.
11. Aug 2020 17:59:59 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:48:51 CEST jreher Updated APD location via API.
28. Jan 2020 15:23:52 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:46:28 CET jreher Updated APD location via API.
27. Nov 2019 19:47:19 CET jreher Updated APD location via API.
25. Nov 2019 17:19:18 CET jreher Updated box and position via API.
23. Aug 2019 11:58:18 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:50:39 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:00 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:26 CEST Tobias Imported from Hamamatsu datasheet.