RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2818032253 - Archived data from Mon, 17. May 2021 09:14:53 CEST


This is all the information about APD 2818032253. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2818032253
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D13
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 382.1 V
Dark current: 14.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 98
Position in Box: 34
EP1 batch: 94
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.4634436 V     T = -25 °C: 346.7412118 V
Voltage for Gain 150: T = +20 °C: 390.2432375 V     T = -25 °C: 354.1047681 V
Voltage for Gain 200: T = +20 °C: 394.5719231 V     T = -25 °C: 358.2269553 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.483379792 V-1     T = -25 °C: 5.022413171 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.871215942 V-1     T = -25 °C: 9.396564696 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.54385825 V-1     T = -25 °C: 14.99368306 V-1
Break-through voltage: T = +20 °C: 409.6981087 V     T = -25 °C: 373.1836963 V
   
Notes:


Version history

Time Author Change comment
11. Jul 2022 14:24:20 CEST oafedulidis Assigned to capsule by script
17. May 2021 09:14:53 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:01:01 CET jreher Updated box and position via API.
11. Aug 2020 18:05:12 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:31 CEST jreher Updated APD location via API.
17. Feb 2020 17:49:58 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:58 CET jreher Updated APD location via API.
27. Nov 2019 19:46:19 CET jreher Updated APD location via API.
25. Nov 2019 17:18:45 CET jreher Updated box and position via API.
20. Aug 2019 12:44:49 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:49:41 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:56 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:20 CEST Tobias Imported from Hamamatsu datasheet.