RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2818032196 - Archived data from Tue, 11. August 2020 18:05:04 CEST


This is all the information about APD 2818032196. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2818032196
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F04
Break-through voltage: 406 V
Voltage for Gain 100 (T=+25°C): 378 V
Dark current: 8.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 97
Position in Box: 44
EP1 batch: 93
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 377.689678 V     T = -25 °C: 342.8378852 V
Voltage for Gain 150: T = +20 °C: 385.4969597 V     T = -25 °C: 350.1456336 V
Voltage for Gain 200: T = +20 °C: 389.8606603 V     T = -25 °C: 354.2575235 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.42729791 V-1     T = -25 °C: 5.062997324 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.621338167 V-1     T = -25 °C: 9.532361522 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.96447759 V-1     T = -25 °C: 15.02743385 V-1
Break-through voltage: T = +20 °C: 405.0626395 V     T = -25 °C: 369.2830939 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:00:54 CET jreher Updated box and position via API.
11. Aug 2020 18:05:04 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:27 CEST jreher Updated APD location via API.
17. Feb 2020 17:50:54 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:55 CET jreher Updated APD location via API.
27. Nov 2019 19:46:08 CET jreher Updated APD location via API.
25. Nov 2019 17:18:41 CET jreher Updated box and position via API.
20. Aug 2019 12:44:23 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:49:11 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:55 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:18 CEST Tobias Imported from Hamamatsu datasheet.