RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2817032176 - Archived data from Tue, 11. August 2020 18:05:02 CEST


This is all the information about APD 2817032176. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2817032176
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G10
Break-through voltage: 406 V
Voltage for Gain 100 (T=+25°C): 379.7 V
Dark current: 14.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 97
Position in Box: 38
EP1 batch: 92
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.2419279 V     T = -25 °C: 344.5327113 V
Voltage for Gain 150: T = +20 °C: 387.062487 V     T = -25 °C: 351.7412417 V
Voltage for Gain 200: T = +20 °C: 391.4218748 V     T = -25 °C: 355.7867538 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.547372714 V-1     T = -25 °C: 4.787397316 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.882592821 V-1     T = -25 °C: 9.906314749 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.61126005 V-1     T = -25 °C: 15.93015872 V-1
Break-through voltage: T = +20 °C: 406.3966431 V     T = -25 °C: 370.3469263 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:00:53 CET jreher Updated box and position via API.
11. Aug 2020 18:05:02 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:27 CEST jreher Updated APD location via API.
17. Feb 2020 17:50:54 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:54 CET jreher Updated APD location via API.
27. Nov 2019 19:46:08 CET jreher Updated APD location via API.
25. Nov 2019 17:18:41 CET jreher Updated box and position via API.
23. Aug 2019 10:15:31 CEST spankonin Updated APD batch assignment via API.
20. Aug 2019 12:44:07 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:49:10 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:54 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:18 CEST Tobias Imported from Hamamatsu datasheet.