RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2817032171 - Archived data from Wed, 16. June 2021 15:58:54 CEST


This is all the information about APD 2817032171. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2817032171
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G11
Break-through voltage: 405 V
Voltage for Gain 100 (T=+25°C): 380.2 V
Dark current: 15.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 97
Position in Box: 35
EP1 batch: 92
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.66137 V     T = -25 °C: 344.4572331 V
Voltage for Gain 150: T = +20 °C: 387.523855 V     T = -25 °C: 351.8183793 V
Voltage for Gain 200: T = +20 °C: 391.8794684 V     T = -25 °C: 355.9489697 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.388670404 V-1     T = -25 °C: 4.777199861 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.475790292 V-1     T = -25 °C: 9.67296389 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.6756891 V-1     T = -25 °C: 15.3639309 V-1
Break-through voltage: T = +20 °C: 406.5967383 V     T = -25 °C: 370.9599368 V
   
Notes:


Version history

Time Author Change comment
16. Nov 2021 09:41:48 CET oafedulidis Assigned to capsule by script
16. Jun 2021 16:02:36 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:58:54 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:51:44 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:00:53 CET jreher Updated box and position via API.
11. Aug 2020 18:05:02 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:26 CEST jreher Updated APD location via API.
17. Feb 2020 17:50:53 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:54 CET jreher Updated APD location via API.
27. Nov 2019 19:46:08 CET jreher Updated APD location via API.
25. Nov 2019 17:18:41 CET jreher Updated box and position via API.
23. Aug 2019 10:15:31 CEST spankonin Updated APD batch assignment via API.
20. Aug 2019 12:44:07 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:49:10 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:54 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:18 CEST Tobias Imported from Hamamatsu datasheet.