RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2817032159 - Archived data from Tue, 11. August 2020 18:05:00 CEST


This is all the information about APD 2817032159. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2817032159
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F08
Break-through voltage: 406 V
Voltage for Gain 100 (T=+25°C): 378.2 V
Dark current: 8.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 97
Position in Box: 25
EP1 batch: 92
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 377.9087993 V     T = -25 °C: 342.6557317 V
Voltage for Gain 150: T = +20 °C: 385.7296629 V     T = -25 °C: 349.9783016 V
Voltage for Gain 200: T = +20 °C: 390.0808174 V     T = -25 °C: 354.0837703 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.652994485 V-1     T = -25 °C: 4.702894145 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.230824504 V-1     T = -25 °C: 9.586916084 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.44989379 V-1     T = -25 °C: 15.25478108 V-1
Break-through voltage: T = +20 °C: 405.4297733 V     T = -25 °C: 369.1550006 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:00:52 CET jreher Updated box and position via API.
11. Aug 2020 18:05:00 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:25 CEST jreher Updated APD location via API.
17. Feb 2020 17:50:53 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:53 CET jreher Updated APD location via API.
27. Nov 2019 19:46:07 CET jreher Updated APD location via API.
25. Nov 2019 17:18:40 CET jreher Updated box and position via API.
23. Aug 2019 10:15:30 CEST spankonin Updated APD batch assignment via API.
20. Aug 2019 12:44:06 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:49:09 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:54 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:18 CEST Tobias Imported from Hamamatsu datasheet.