RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2817032139 - Archived data from Mon, 16. May 2022 13:33:56 CEST


This is all the information about APD 2817032139. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2817032139
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F13
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 379.3 V
Dark current: 17.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 97
Position in Box: 16
EP1 batch: 92
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 378.5243278 V     T = -25 °C: 343.1740845 V
Voltage for Gain 150: T = +20 °C: 386.3584896 V     T = -25 °C: 350.5352571 V
Voltage for Gain 200: T = +20 °C: 390.7166077 V     T = -25 °C: 354.6487004 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.461015872 V-1     T = -25 °C: 4.882122121 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.677906946 V-1     T = -25 °C: 9.032698388 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.13828167 V-1     T = -25 °C: 16.15315479 V-1
Break-through voltage: T = +20 °C: 405.9476944 V     T = -25 °C: 369.5512351 V
   
Notes:


Version history

Time Author Change comment
16. Nov 2022 11:27:09 CET oafedulidis Assigned to capsule by script
16. May 2022 13:33:56 CEST oafedulidis Updated box and position via API.
28. Apr 2021 13:29:15 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:00:51 CET jreher Updated box and position via API.
11. Aug 2020 18:04:58 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:25 CEST jreher Updated APD location via API.
17. Feb 2020 17:50:52 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:53 CET jreher Updated APD location via API.
27. Nov 2019 19:46:06 CET jreher Updated APD location via API.
25. Nov 2019 17:18:39 CET jreher Updated box and position via API.
23. Aug 2019 10:15:29 CEST spankonin Updated APD batch assignment via API.
20. Aug 2019 12:44:06 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:49:09 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:53 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:17 CEST Tobias Imported from Hamamatsu datasheet.