Subdetector specification:  
Serial: 2817032123
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B08
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 381.4 V
Dark current: 7.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 97
Position in Box: 8
EP1 batch: 91
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.7101702 V     T = -25 °C: 346.2189938 V
Voltage for Gain 150: T = +20 °C: 389.50369 V     T = -25 °C: 353.6089007 V
Voltage for Gain 200: T = +20 °C: 393.8262526 V     T = -25 °C: 357.737672 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.747575097 V-1     T = -25 °C: 4.852073302 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.598877587 V-1     T = -25 °C: 9.888286749 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.99937528 V-1     T = -25 °C: 15.87290078 V-1
Break-through voltage: T = +20 °C: 408.5001607 V     T = -25 °C: 372.4986024 V
   
Notes:


Version history

Time Author Change comment
16. Nov 2021 09:41:05 CET oafedulidis Assigned to capsule by script
03. May 2021 15:20:06 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:00:50 CET jreher Updated box and position via API.
11. Aug 2020 18:04:57 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:24 CEST jreher Updated APD location via API.
17. Feb 2020 17:52:56 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:52 CET jreher Updated APD location via API.
27. Nov 2019 19:46:06 CET jreher Updated APD location via API.
25. Nov 2019 17:18:39 CET jreher Updated box and position via API.
20. Aug 2019 12:40:48 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:49:08 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:53 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:17 CEST Tobias Imported from Hamamatsu datasheet.