Subdetector specification:  
Serial: 2816032080
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C11
Break-through voltage: 413 V
Voltage for Gain 100 (T=+25°C): 385.4 V
Dark current: 9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 96
Position in Box: 33
EP1 batch: 91
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.8948605 V     T = -25 °C: 350.2241634 V
Voltage for Gain 150: T = +20 °C: 393.6384627 V     T = -25 °C: 357.5899783 V
Voltage for Gain 200: T = +20 °C: 397.9069492 V     T = -25 °C: 361.6910239 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.702875653 V-1     T = -25 °C: 4.84837152 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.500065257 V-1     T = -25 °C: 10.0004422 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.05341848 V-1     T = -25 °C: 16.08600216 V-1
Break-through voltage: T = +20 °C: 412.7149515 V     T = -25 °C: 376.4417986 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:00:45 CET jreher Updated box and position via API.
11. Aug 2020 17:59:28 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:21 CEST jreher Updated APD location via API.
28. Jan 2020 14:41:02 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:50 CET jreher Updated APD location via API.
27. Nov 2019 19:45:56 CET jreher Updated APD location via API.
25. Nov 2019 17:18:36 CET jreher Updated box and position via API.
20. Aug 2019 12:40:47 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:49:02 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:52 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:16 CEST Tobias Imported from Hamamatsu datasheet.