Show Hamamatsu Avalanche Photo Diode 2816032070 - Archived data from Thu, 15. April 2021 17:01:14 CEST
This is all the information about APD 2816032070. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2816032070 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | E06 |
Break-through voltage: | 410 V |
Voltage for Gain 100 (T=+25°C): | 381.2 V |
Dark current: | 8.9 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 96 |
Position in Box: | 23 |
EP1 batch: | 90 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 381.3180776 V T = -25 °C: 345.791223 V |
Voltage for Gain 150: | T = +20 °C: 389.0976901 V T = -25 °C: 353.1007489 V |
Voltage for Gain 200: | T = +20 °C: 393.4313202 V T = -25 °C: 357.2016481 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.554113369 V-1 T = -25 °C: 5.037462736 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.930513514 V-1 T = -25 °C: 9.480116385 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.70650143 V-1 T = -25 °C: 14.95852111 V-1 |
Break-through voltage: | T = +20 °C: 409.0072759 V T = -25 °C: 372.3986625 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
25. Oct 2021 14:22:52 CEST | oafedulidis | Assigned to capsule by script |
15. Apr 2021 17:01:14 CEST | jreher | Updated box and position via API. |
05. Feb 2021 11:00:44 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:59:26 CEST | jreher | Updated APD characteristics via API. |
11. Aug 2020 17:55:20 CEST | jreher | Updated APD location via API. |
28. Jan 2020 14:41:01 CET | spankonin | Updated APD batch assignment via API. |
29. Nov 2019 11:50:50 CET | jreher | Updated APD location via API. |
27. Nov 2019 19:45:56 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:18:35 CET | jreher | Updated box and position via API. |
20. Aug 2019 12:43:32 CEST | jgrochowski | Updated APD batch assignment via API. |
05. Jul 2019 13:49:01 CEST | jreher | Updated APD location via API. |
03. Jan 2019 00:13:52 CET | Tobias | Corrected dark current unit. |
20. Jun 2018 13:36:16 CEST | Tobias | Imported from Hamamatsu datasheet. |