RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2816032060 - Archived data from Tue, 11. August 2020 17:59:24 CEST


This is all the information about APD 2816032060. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2816032060
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B05
Break-through voltage: 413 V
Voltage for Gain 100 (T=+25°C): 385.1 V
Dark current: 8.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 96
Position in Box: 14
EP1 batch: 90
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.9716656 V     T = -25 °C: 350.2013138 V
Voltage for Gain 150: T = +20 °C: 393.7627069 V     T = -25 °C: 357.6075702 V
Voltage for Gain 200: T = +20 °C: 398.0696011 V     T = -25 °C: 361.7302048 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.656181188 V-1     T = -25 °C: 4.845358093 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.337993743 V-1     T = -25 °C: 9.003063596 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.73876289 V-1     T = -25 °C: 15.9849419 V-1
Break-through voltage: T = +20 °C: 412.4476735 V     T = -25 °C: 376.1030477 V
   
Notes:


Version history

Time Author Change comment
11. Jul 2022 14:25:44 CEST oafedulidis Assigned to capsule by script
16. Jun 2021 16:03:43 CEST oafedulidis Updated box and position via API.
16. Jun 2021 16:00:00 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:52:41 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:00:43 CET jreher Updated box and position via API.
11. Aug 2020 17:59:24 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:19 CEST jreher Updated APD location via API.
28. Jan 2020 14:41:01 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:49 CET jreher Updated APD location via API.
27. Nov 2019 19:45:55 CET jreher Updated APD location via API.
25. Nov 2019 17:18:34 CET jreher Updated box and position via API.
20. Aug 2019 12:43:31 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:49:01 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:52 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:15 CEST Tobias Imported from Hamamatsu datasheet.