RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2816032042 - Archived data from Tue, 11. August 2020 17:59:22 CEST


This is all the information about APD 2816032042. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2816032042
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E09
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.2 V
Dark current: 9.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 96
Position in Box: 1
EP1 batch: 90
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.7190123 V     T = -25 °C: 346.3429704 V
Voltage for Gain 150: T = +20 °C: 389.5236506 V     T = -25 °C: 353.6506697 V
Voltage for Gain 200: T = +20 °C: 393.8507449 V     T = -25 °C: 357.7302548 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.734202548 V-1     T = -25 °C: 4.857104525 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.579669132 V-1     T = -25 °C: 10.02290213 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.96338653 V-1     T = -25 °C: 16.05052382 V-1
Break-through voltage: T = +20 °C: 409.6383558 V     T = -25 °C: 373.0998439 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:00:41 CET jreher Updated box and position via API.
11. Aug 2020 17:59:22 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:18 CEST jreher Updated APD location via API.
28. Jan 2020 14:39:34 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:48 CET jreher Updated APD location via API.
27. Nov 2019 19:45:54 CET jreher Updated APD location via API.
25. Nov 2019 17:18:33 CET jreher Updated box and position via API.
20. Aug 2019 12:43:30 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:49:00 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:51 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:14 CEST Tobias Imported from Hamamatsu datasheet.