Show Hamamatsu Avalanche Photo Diode 2815031960 - Archived data from Thu, 03. January 2019 00:13:50 CET
This is all the information about APD 2815031960. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2815031960 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | unknown |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | E10 |
Break-through voltage: | 405 V |
Voltage for Gain 100 (T=+25°C): | 377 V |
Dark current: | 7.6 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 94 |
Position in Box: | 39 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
26. Oct 2021 10:25:38 CEST | oafedulidis | Assigned to capsule by script |
28. Apr 2021 13:27:31 CEST | oafedulidis | Updated box and position via API. |
05. Feb 2021 11:00:30 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:25:58 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:59:19 CEST | jreher | Updated APD characteristics via API. |
11. Aug 2020 17:55:17 CEST | jreher | Updated APD location via API. |
28. Jan 2020 14:39:33 CET | spankonin | Updated APD batch assignment via API. |
29. Nov 2019 11:50:43 CET | jreher | Updated APD location via API. |
27. Nov 2019 19:45:35 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:18:27 CET | jreher | Updated box and position via API. |
20. Aug 2019 12:35:49 CEST | jgrochowski | Updated APD batch assignment via API. |
05. Jul 2019 13:48:46 CEST | jreher | Updated APD location via API. |
03. Jan 2019 00:13:50 CET | Tobias | Corrected dark current unit. |
20. Jun 2018 13:36:12 CEST | Tobias | Imported from Hamamatsu datasheet. |