Serial: 2813031799
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C02
Break-through voltage: 416 V
Voltage for Gain 100 (T=+25°C): 387.4 V
Dark current: 5.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 93
Position in Box: 6
EP1 batch: 85
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 387.3066827 V     T = -25 °C: 351.596166 V
Voltage for Gain 150: T = +20 °C: 395.2168841 V     T = -25 °C: 359.1141488 V
Voltage for Gain 200: T = +20 °C: 399.6059745 V     T = -25 °C: 363.3427106 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.479805851 V-1     T = -25 °C: 4.597993755 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.723572213 V-1     T = -25 °C: 9.189421226 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.14200422 V-1     T = -25 °C: 14.26686859 V-1
Break-through voltage: T = +20 °C: 415.1839034 V     T = -25 °C: 378.9177507 V
   
Notes:


Version history

Time Author Change comment
16. Nov 2021 10:41:37 CET oafedulidis Assigned to capsule by script
27. Aug 2021 10:31:11 CEST oafedulidis Updated box and position via API.
03. May 2021 10:26:04 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:00:19 CET jreher Updated box and position via API.
03. Feb 2021 18:25:46 CET jreher Updated box and position via API.
11. Aug 2020 17:59:04 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:10 CEST jreher Updated APD location via API.
28. Jan 2020 14:22:10 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:37 CET jreher Updated APD location via API.
27. Nov 2019 19:45:21 CET jreher Updated APD location via API.
25. Nov 2019 17:18:17 CET jreher Updated box and position via API.
20. Aug 2019 12:34:41 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:48:36 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:47 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:09 CEST Tobias Imported from Hamamatsu datasheet.