Subdetector specification:  
Serial: 2813031776
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: A09
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 385.1 V
Dark current: 9.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 92
Position in Box: 42
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.1240353 V     T = -25 °C: 349.3823354 V
Voltage for Gain 150: T = +20 °C: 392.9908062 V     T = -25 °C: 356.8740329 V
Voltage for Gain 200: T = +20 °C: 397.365369 V     T = -25 °C: 361.0669824 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.578174422 V-1     T = -25 °C: 4.740420271 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.987837692 V-1     T = -25 °C: 9.538356255 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.04149164 V-1     T = -25 °C: 15.10400119 V-1
Break-through voltage: T = +20 °C: 412.1946063 V     T = -25 °C: 376.0259513 V
   
Notes:


Version history

Time Author Change comment
26. Oct 2021 10:34:13 CEST oafedulidis Assigned to capsule by script
15. Apr 2021 17:01:21 CEST jreher Updated box and position via API.
05. Feb 2021 11:00:14 CET jreher Updated box and position via API.
03. Feb 2021 18:25:42 CET jreher Updated box and position via API.
11. Aug 2020 18:04:54 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:08 CEST jreher Updated APD location via API.
17. Feb 2020 17:52:55 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:36 CET jreher Updated APD location via API.
27. Nov 2019 19:45:12 CET jreher Updated APD location via API.
25. Nov 2019 17:18:15 CET jreher Updated box and position via API.
05. Jul 2019 13:48:31 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:46 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:08 CEST Tobias Imported from Hamamatsu datasheet.