RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2812031730 - Archived data from Wed, 03. February 2021 18:25:39 CET


This is all the information about APD 2812031730. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2812031730
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C03
Break-through voltage: 405 V
Voltage for Gain 100 (T=+25°C): 380.5 V
Dark current: 8.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 92
Position in Box: 17
EP1 batch: 84
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.5343391 V     T = -25 °C: 345.2808219 V
Voltage for Gain 150: T = +20 °C: 388.4196514 V     T = -25 °C: 352.7615502 V
Voltage for Gain 200: T = +20 °C: 392.8080093 V     T = -25 °C: 356.8912544 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.43859752 V-1     T = -25 °C: 4.793249006 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.551955061 V-1     T = -25 °C: 9.696912486 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.7205051 V-1     T = -25 °C: 15.90262593 V-1
Break-through voltage: T = +20 °C: 408.8434615 V     T = -25 °C: 372.6243873 V
   
Notes:


Version history

Time Author Change comment
17. Jun 2021 19:22:28 CEST oafedulidis Assigned to capsule by script
16. Feb 2021 12:27:18 CET jreher Updated box and position via API.
05. Feb 2021 11:00:11 CET jreher Updated box and position via API.
03. Feb 2021 18:25:39 CET jreher Updated box and position via API.
11. Aug 2020 18:04:49 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:06 CEST jreher Updated APD location via API.
17. Feb 2020 17:54:22 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:34 CET jreher Updated APD location via API.
27. Nov 2019 19:45:11 CET jreher Updated APD location via API.
25. Nov 2019 17:18:13 CET jreher Updated box and position via API.
20. Aug 2019 12:34:21 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:48:29 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:46 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:07 CEST Tobias Imported from Hamamatsu datasheet.