Subdetector specification:  
Serial: 2812031698
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C04
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 380.1 V
Dark current: 9.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 91
Position in Box: 40
EP1 batch: 83
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.0140009 V     T = -25 °C: 344.794658 V
Voltage for Gain 150: T = +20 °C: 387.9065627 V     T = -25 °C: 352.2032808 V
Voltage for Gain 200: T = +20 °C: 392.3179011 V     T = -25 °C: 356.3778297 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.589525473 V-1     T = -25 °C: 4.979636855 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.978990437 V-1     T = -25 °C: 9.231232487 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.80727006 V-1     T = -25 °C: 14.4373838 V-1
Break-through voltage: T = +20 °C: 408.1836953 V     T = -25 °C: 371.9260881 V
   
Notes:


Version history

Time Author Change comment
09. Feb 2021 11:21:07 CET jreher Assigned to capsule by script
05. Feb 2021 11:00:06 CET jreher Updated box and position via API.
03. Feb 2021 18:25:34 CET jreher Updated box and position via API.
18. Dec 2020 13:59:26 CET jreher Updated box and position via API.
11. Aug 2020 18:04:44 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:04 CEST jreher Updated APD location via API.
17. Feb 2020 17:54:54 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:32 CET jreher Updated APD location via API.
27. Nov 2019 19:45:01 CET jreher Updated APD location via API.
25. Nov 2019 17:18:10 CET jreher Updated box and position via API.
20. Aug 2019 12:33:53 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:48:22 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:45 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:06 CEST Tobias Imported from Hamamatsu datasheet.