Show Hamamatsu Avalanche Photo Diode 2811031633 - Archived data from Wed, 28. April 2021 13:28:26 CEST


This is all the information about APD 2811031633. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2811031633
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F04
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 381.9 V
Dark current: 5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 91
Position in Box: 1
EP1 batch: 82
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.9976925 V     T = -25 °C: 346.3973365 V
Voltage for Gain 150: T = +20 °C: 389.7682324 V     T = -25 °C: 353.8252255 V
Voltage for Gain 200: T = +20 °C: 394.0993606 V     T = -25 °C: 357.9839832 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.688653737 V-1     T = -25 °C: 4.708149549 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.217105711 V-1     T = -25 °C: 9.651755902 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.49037301 V-1     T = -25 °C: 15.4065324 V-1
Break-through voltage: T = +20 °C: 409.1445235 V     T = -25 °C: 373.3543197 V
   
Notes:


Version history

Time Author Change comment
18. May 2022 09:59:29 CEST oafedulidis Assigned to capsule by script
28. Apr 2021 13:28:26 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:00:01 CET jreher Updated box and position via API.
03. Feb 2021 18:25:30 CET jreher Updated box and position via API.
11. Aug 2020 18:04:36 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:00 CEST jreher Updated APD location via API.
17. Feb 2020 17:55:22 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:29 CET jreher Updated APD location via API.
27. Nov 2019 19:44:58 CET jreher Updated APD location via API.
25. Nov 2019 17:18:07 CET jreher Updated box and position via API.
20. Aug 2019 12:32:45 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:48:19 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:43 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:04 CEST Tobias Imported from Hamamatsu datasheet.