Show Hamamatsu Avalanche Photo Diode 0803007414 - Archived data from Wed, 03. February 2021 18:20:40 CET


This is all the information about APD 0803007414. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0803007414
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F10
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 382.8 V
Dark current: 3.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 52
Position in Box: 31
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 04. Jun 2019
Return for assembly: none
   
Irradiation:  
Date: 29. May 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 29. May 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.3209469 V     T = -25 °C: 346.4109756 V
Voltage for Gain 150: T = +20 °C: 390.1820447 V     T = -25 °C: 353.8398871 V
Voltage for Gain 200: T = +20 °C: 394.530536 V     T = -25 °C: 358.0256223 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.422150038 V-1     T = -25 °C: 4.659433216 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.552346236 V-1     T = -25 °C: 9.227745331 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.61216037 V-1     T = -25 °C: 16.12997914 V-1
Break-through voltage: T = +20 °C: 409.3389892 V     T = -25 °C: 372.5090441 V
   
Notes:


Version history

Time Author Change comment
10. Jun 2022 12:15:03 CEST oafedulidis Assigned to capsule by script
27. Aug 2021 11:12:27 CEST oafedulidis Updated box and position via API.
21. Apr 2021 14:48:26 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:55:05 CET jreher Updated box and position via API.
03. Feb 2021 18:20:40 CET jreher Updated box and position via API.
11. Aug 2020 17:27:35 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:37:55 CET jreher Updated APD location via API.
25. Nov 2019 17:15:02 CET jreher Updated box and position via API.
04. Jul 2019 11:12:20 CEST jreher Updated APD location via API.
18. Jun 2019 13:12:27 CEST jgrochowski Updated APD batch assignment via API.
04. Jun 2019 15:50:46 CEST markus.moritz
22. Jun 2016 15:22:36 CEST Tobias Imported from Hamamatsu datasheet.