Show Hamamatsu Avalanche Photo Diode 2810031604 - Archived data from Tue, 11. August 2020 18:04:32 CEST


This is all the information about APD 2810031604. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2810031604
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C03
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 378.7 V
Dark current: 6.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 90
Position in Box: 31
EP1 batch: 81
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 378.6093596 V     T = -25 °C: 343.6407452 V
Voltage for Gain 150: T = +20 °C: 386.4932452 V     T = -25 °C: 351.003705 V
Voltage for Gain 200: T = +20 °C: 390.8815477 V     T = -25 °C: 355.1541457 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.38288499 V-1     T = -25 °C: 4.681936036 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.449120425 V-1     T = -25 °C: 9.423750515 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.4839638 V-1     T = -25 °C: 14.7499132 V-1
Break-through voltage: T = +20 °C: 407.0631948 V     T = -25 °C: 370.8918132 V
   
Notes:


Version history

Time Author Change comment
26. Oct 2021 10:30:13 CEST oafedulidis Assigned to capsule by script
21. Apr 2021 11:02:57 CEST jreher Updated box and position via API.
05. Feb 2021 10:59:57 CET jreher Updated box and position via API.
03. Feb 2021 18:25:26 CET jreher Updated box and position via API.
11. Aug 2020 18:04:32 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:54:58 CEST jreher Updated APD location via API.
17. Feb 2020 17:56:12 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:27 CET jreher Updated APD location via API.
27. Nov 2019 19:44:49 CET jreher Updated APD location via API.
25. Nov 2019 17:18:05 CET jreher Updated box and position via API.
20. Aug 2019 12:31:31 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:48:14 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:42 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:04 CEST Tobias Imported from Hamamatsu datasheet.