Show Hamamatsu Avalanche Photo Diode 2810031584 - Archived data from Wed, 27. November 2019 19:44:48 CET
This is all the information about APD 2810031584. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2810031584 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D12 |
Break-through voltage: | 411 V |
Voltage for Gain 100 (T=+25°C): | 383.4 V |
Dark current: | 8.8 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 90 |
Position in Box: | 17 |
EP1 batch: | 80 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
16. Feb 2021 12:25:42 CET | jreher | Updated box and position via API. |
15. Feb 2021 15:39:59 CET | jreher | Assigned to capsule by script |
05. Feb 2021 10:59:56 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:25:24 CET | jreher | Updated box and position via API. |
11. Aug 2020 18:04:29 CEST | jreher | Updated APD characteristics via API. |
11. Aug 2020 17:54:57 CEST | jreher | Updated APD location via API. |
17. Feb 2020 17:56:11 CET | spankonin | Updated APD batch assignment via API. |
29. Nov 2019 11:50:26 CET | jreher | Updated APD location via API. |
27. Nov 2019 19:44:48 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:18:04 CET | jreher | Updated box and position via API. |
20. Aug 2019 12:17:17 CEST | jreher | Updated APD batch assignment via API. |
05. Jul 2019 13:48:13 CEST | jreher | Updated APD location via API. |
03. Jan 2019 00:13:42 CET | Tobias | Corrected dark current unit. |
20. Jun 2018 13:36:03 CEST | Tobias | Imported from Hamamatsu datasheet. |