Show Hamamatsu Avalanche Photo Diode 2810031573 - Archived data from Mon, 25. November 2019 17:18:03 CET


This is all the information about APD 2810031573. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2810031573
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum Box 90
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B07
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.9 V
Dark current: 8.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 90
Position in Box: 9
EP1 batch: 80
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:59:54 CET jreher Updated box and position via API.
03. Feb 2021 18:25:23 CET jreher Updated box and position via API.
11. Aug 2020 18:04:27 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:54:56 CEST jreher Updated APD location via API.
17. Feb 2020 17:56:10 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:26 CET jreher Updated APD location via API.
27. Nov 2019 19:44:48 CET jreher Updated APD location via API.
25. Nov 2019 17:18:03 CET jreher Updated box and position via API.
20. Aug 2019 12:17:17 CEST jreher Updated APD batch assignment via API.
05. Jul 2019 13:48:12 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:42 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:03 CEST Tobias Imported from Hamamatsu datasheet.