RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2808031433 - Archived data from Wed, 03. February 2021 18:25:08 CET


This is all the information about APD 2808031433. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2808031433
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D14
Break-through voltage: 418 V
Voltage for Gain 100 (T=+25°C): 390 V
Dark current: 17.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 88
Position in Box: 17
EP1 batch: 77
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 390.8051742 V     T = -25 °C: 354.4345207 V
Voltage for Gain 150: T = +20 °C: 398.5935647 V     T = -25 °C: 361.9417942 V
Voltage for Gain 200: T = +20 °C: 402.878073 V     T = -25 °C: 366.1309672 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.713033478 V-1     T = -25 °C: 4.693490908 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.603313735 V-1     T = -25 °C: 9.464786672 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.12998427 V-1     T = -25 °C: 15.02585777 V-1
Break-through voltage: T = +20 °C: 416.9267863 V     T = -25 °C: 380.4692786 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:59:39 CET jreher Updated box and position via API.
03. Feb 2021 18:25:08 CET jreher Updated box and position via API.
11. Aug 2020 17:39:26 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:44:26 CET jreher Updated APD location via API.
25. Nov 2019 17:17:54 CET jreher Updated box and position via API.
13. Sep 2019 10:30:22 CEST jgrochowski Updated APD batch assignment via API.
04. Sep 2019 13:21:31 CEST markus.moritz
25. Jul 2019 12:11:10 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:47:56 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:38 CET Tobias Corrected dark current unit.
20. Jun 2018 13:35:57 CEST Tobias Imported from Hamamatsu datasheet.