RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2806031271 - Archived data from Wed, 03. February 2021 18:25:02 CET


This is all the information about APD 2806031271. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2806031271
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C05
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379 V
Dark current: 7.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 296
Position in Box: 42
EP1 batch: 76
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.0933117 V     T = -25 °C: 344.0112452 V
Voltage for Gain 150: T = +20 °C: 386.9737885 V     T = -25 °C: 351.3935868 V
Voltage for Gain 200: T = +20 °C: 391.3914729 V     T = -25 °C: 355.5393803 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.561679624 V-1     T = -25 °C: 4.907644132 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.922901636 V-1     T = -25 °C: 9.095028731 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.43786863 V-1     T = -25 °C: 16.08019093 V-1
Break-through voltage: T = +20 °C: 407.5925758 V     T = -25 °C: 371.1101936 V
   
Notes:


Version history

Time Author Change comment
26. Oct 2021 09:59:30 CEST oafedulidis Assigned to capsule by script
10. May 2021 14:00:12 CEST oafedulidis Updated box and position via API.
21. Apr 2021 14:48:08 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:59:33 CET jreher Updated box and position via API.
03. Feb 2021 18:25:02 CET jreher Updated box and position via API.
11. Aug 2020 17:39:20 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:44:16 CET jreher Updated APD location via API.
25. Nov 2019 17:17:49 CET jreher Updated box and position via API.
13. Sep 2019 10:30:00 CEST jgrochowski Updated APD batch assignment via API.
04. Sep 2019 13:54:45 CEST markus.moritz
25. Jul 2019 12:11:24 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:47:49 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:37 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:06:11 CEST Tobias Imported from Hamamatsu datasheet.