Subdetector specification:  
Serial: 2805031177
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2319025743/2805031177
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: E08
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 380 V
Dark current: 5.5 nA
   
Screening Logistics:  
Available: No
Storage Box: 86
Position in Box: 25
EP1 batch: 75
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.6772212 V     T = -25 °C: 344.223372 V
Voltage for Gain 150: T = +20 °C: 387.4440507 V     T = -25 °C: 351.5681584 V
Voltage for Gain 200: T = +20 °C: 391.7647958 V     T = -25 °C: 355.6523556 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.444920245 V-1     T = -25 °C: 4.909667736 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.721316908 V-1     T = -25 °C: 9.097761099 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.19095781 V-1     T = -25 °C: 16.22594019 V-1
Break-through voltage: T = +20 °C: 406.6171739 V     T = -25 °C: 370.0432539 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:59:27 CET jreher Updated box and position via API.
03. Feb 2021 18:24:55 CET jreher Updated box and position via API.
11. Aug 2020 17:39:12 CEST jreher Updated APD characteristics via API.
25. Jun 2020 11:14:25 CEST jreher Assigned to capsule by script
20. Feb 2020 13:34:40 CET jreher Updated box and position via API.
27. Nov 2019 19:44:06 CET jreher Updated APD location via API.
25. Nov 2019 17:17:44 CET jreher Updated box and position via API.
13. Sep 2019 10:29:39 CEST jgrochowski Updated APD batch assignment via API.
04. Sep 2019 13:38:27 CEST markus.moritz
25. Jul 2019 12:11:41 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:47:42 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:35 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:05:50 CEST Tobias Imported from Hamamatsu datasheet.