Show Hamamatsu Avalanche Photo Diode 2804031109 - Archived data from Fri, 18. December 2020 14:00:18 CET


This is all the information about APD 2804031109. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2804031109
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F11
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 380.7 V
Dark current: 12.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 85
Position in Box: 50
EP1 batch: 74
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.983415 V     T = -25 °C: 345.63154 V
Voltage for Gain 150: T = +20 °C: 388.7882618 V     T = -25 °C: 352.9762031 V
Voltage for Gain 200: T = +20 °C: 393.1268448 V     T = -25 °C: 357.0926077 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.606020369 V-1     T = -25 °C: 4.695528897 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.200355749 V-1     T = -25 °C: 9.54217855 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.37431609 V-1     T = -25 °C: 15.14573344 V-1
Break-through voltage: T = +20 °C: 408.2299397 V     T = -25 °C: 371.9705529 V
   
Notes:


Version history

Time Author Change comment
09. Feb 2021 11:22:17 CET jreher Assigned to capsule by script
05. Feb 2021 10:59:22 CET jreher Updated box and position via API.
03. Feb 2021 18:24:51 CET jreher Updated box and position via API.
18. Dec 2020 14:00:18 CET jreher Updated box and position via API.
11. Aug 2020 17:39:08 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:43:57 CET jreher Updated APD location via API.
25. Nov 2019 17:17:41 CET jreher Updated box and position via API.
13. Sep 2019 10:29:16 CEST jgrochowski Updated APD batch assignment via API.
04. Sep 2019 13:29:35 CEST markus.moritz
25. Jul 2019 12:12:00 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:47:36 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:35 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:05:40 CEST Tobias Imported from Hamamatsu datasheet.