RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2804031071 - Archived data from Tue, 11. August 2020 17:39:06 CEST


This is all the information about APD 2804031071. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2804031071
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2307024749/2804031071
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: C03
Break-through voltage: 404 V
Voltage for Gain 100 (T=+25°C): 378.6 V
Dark current: 8.3 nA
   
Screening Logistics:  
Available: No
Storage Box: 85
Position in Box: 38
EP1 batch: 73
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 378.8140965 V     T = -25 °C: 343.5658763 V
Voltage for Gain 150: T = +20 °C: 386.6805606 V     T = -25 °C: 350.9371703 V
Voltage for Gain 200: T = +20 °C: 391.058451 V     T = -25 °C: 355.0852374 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.663922804 V-1     T = -25 °C: 4.732635337 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.251817761 V-1     T = -25 °C: 9.525662963 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.36316129 V-1     T = -25 °C: 15.11579895 V-1
Break-through voltage: T = +20 °C: 406.6115989 V     T = -25 °C: 370.3852693 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:59:20 CET jreher Updated box and position via API.
03. Feb 2021 18:24:50 CET jreher Updated box and position via API.
11. Aug 2020 17:39:06 CEST jreher Updated APD characteristics via API.
03. Apr 2020 09:59:53 CEST jreher Assigned to capsule by script
19. Feb 2020 11:53:33 CET jreher Updated box and position via API.
27. Nov 2019 19:43:56 CET jreher Updated APD location via API.
25. Nov 2019 17:17:40 CET jreher Updated box and position via API.
13. Sep 2019 10:29:15 CEST jgrochowski Updated APD batch assignment via API.
04. Sep 2019 13:26:20 CEST markus.moritz
25. Jul 2019 12:12:16 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:47:35 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:34 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:05:35 CEST Tobias Imported from Hamamatsu datasheet.